B2B procurement · Buyer guide
Compare ball burst strength using finished sheets from identified lots, the same specimen construction and the same method setup. Record individual readings, where each sheet failed and whether the difference is outside the buyer-agreed range. A ball burst result describes resistance to mechanical penetration in that test; it cannot replace wet strength, absorbency or real wiping checks.
This is a procurement comparison plan for tissue paper towels. No Sansheng production-lot result, acceptance threshold or performance superiority is claimed.
Send the exact SKU, buying destination and inspection question you need reviewed.
Reusable procurement data

Direct answer
Compare ball burst strength using finished sheets from identified lots, the same specimen construction and the same method setup. Record individual readings, where each sheet failed and whether the difference is outside the buyer-agreed range. A ball burst result describes resistance to mechanical penetration in that test; it cannot replace wet strength, absorbency or real wiping checks.
Freeze the finished towel construction
Ask the paper towel supplier to identify the exact roll or folded-sheet SKU, ply count, basis weight, embossing, sheet size and relevant perforation or fold. Sample from several cartons or rolls in each identified production lot; do not compare a single hand-picked sheet with a prior shipment average. Record whether the test piece is a finished multi-ply product or a separated ply. Those are different specimens. Keep an approved reference and photographs of the sampled packs so a later investigation can trace the physical construction.

Use one ball burst procedure
ISO 12625-9:2015 specifies a ball burst strength method for tissue paper and tissue products, measuring resistance to mechanical penetration. Its stated setup uses a 50 mm clamping device. Confirm the laboratory procedure, specimen preparation, conditioning, clamping and result units before comparing reports. Mixing a 50 mm result with another clamp or an in-house push-through test would make the comparison hard to interpret. Report the actual method edition and test conditions; the standard does not decide a commercial pass limit for every towel format.

Review the spread, not only the average
Put the individual values from each lot side by side with the approved reference. Mark unusual low readings and note whether failures start at an emboss valley, ply separation, edge defect or another visible feature. Ask for the number of specimens and how they were distributed across rolls or cartons. A narrow average difference may hide a wider tail of weak sheets. If there is a suspected shift, use retained samples from both lots and one controlled retest before changing the specification or issuing a supplier claim.

Connect the lab result to the buyer task
Decide whether penetration resistance matters to the actual handling and dispensing complaint. A towel that survives the ball test may still tear while wet, shed fibers during wiping or absorb slowly. Compare those outcomes with separate methods or buyer-defined use trials. Write the agreed ball burst range into the approval file, specify when to retest after changes in furnish, ply bonding or embossing, and keep lot identifiers beside the raw readings. A paper towel supplier should not infer a 40HQ shipment result from one laboratory sheet.
Buyer comparison record
| Check | Record | Buyer purpose |
|---|---|---|
| Identity | Finished SKU, ply and lot | Compare like with like |
| Test setup | ISO edition, clamp and conditioning | Keep method consistent |
| Distribution | Individual values and failure notes | Detect weak specimens |
| Use decision | Separate wet-use and absorbency checks | Avoid overclaiming |
What should buyers ask the paper towel supplier?
- Finished SKU and production-lot identifiers for every sampled carton
- ISO 12625-9 method edition, laboratory setup and specimen preparation
- Individual ball burst readings with failure notes and retained samples
- Buyer-approved range and rules for a construction change or retest
Send the paper towel supplier your intended use, destination and required acceptance decision.
Paper Towel Supplier: How to Compare Absorption Time and Capacity Reports?
Questions buyers also ask
Is ball burst the same as tensile strength?
No. Ball burst applies a penetration load; tensile pulls a strip. Keep their results separate.
Does a higher result always make a better towel?
No. The intended wiping, absorbency, softness and dispensing needs still matter.
Does ISO 12625-9 set a required supplier pass score?
No. It describes the measurement; the commercial acceptance range needs agreement.
Sources and scope notes
- ISO 12625-9:2015 Supports: Tissue ball burst method and its 50 mm clamp scope. Limit: Does not set a buyer-specific performance limit or prove any Sansheng lot result.
- Sansheng paper towel product page Supports: Identifies the relevant towel product family. Limit: Does not supply this article’s batch readings.
Source scope checked October 26, 2026. Illustrative images do not document a Sansheng test, certified SKU or customer order.
Request an identified sample review
Send the paper towel supplier your exact SKU, approved sample, buying destination and evidence requirement. The record can then be matched to the decision before a quote or release.

Sales Manager at Sansheng Paper · 20+ years in tissue paper OEM & bulk export · LinkedIn